The Iguana - Modular Green Classroom Building
The Iguana is an advanced relocatable 30x32 Modular Green Classroom Design. Meets Collaborative for High Performance Schools (CHPS) specifications.
The Green Advantage
- Extensive use of environmentally friendly & recycled materials
- Energy saving appliances and technologies
- Innovative design and materials for a quieter interior with improved air quality
Building Photos & Floorplans
Download the Iguana Green Classroom Brochure in PDF format. Click the photos to enlarge.
Exterior Envelope
Roof System
- "Cool Roof" membrane (SRI 88)-Energy Star & CA Energy Commission Compliant
- 4" Rigid Insulation, R25 min installed outside interior envelope for reduced heat transfer
- 14" Tubular skylight Solatube system with ceiling light diffuser to reduce artificial lighting demand
- Forestry Stewardship Council Certified 3/4” T&G plywood sheathing
Exterior Wall System
- High recycled content 6" 20ga metal studs (16" o.c.) for stronger and straighter walls
- Thicker R19 batt insulation (Formaldehyde free for better indoor air quality)
- TyVek building wrap vapor barrier to help eliminate drafts
- Lower maintenance exterior cladding: Cement Plaster, Metal Panels, Cementitious Panels, Phenolic panels
- Operable, thermally broken lower maintenance aluminum awning windows with low-E glazing (46% transmittable light) to reduce heat transfer
- Hollow metal exterior door and frame, insulated core R14 with vision glass
Flooring System
- Forestry Stewardship Council Certified 1 1/8" T&G plywood to eliminate seam separation and floor sag
Interior Environment Finishes
Floor Finishes
- Carpet Tile per the Green Label Plus Program
- Durable & VOC Free Forbo Marmoleum linoleum
Walls
- 1/2" Gypsum backer board
- 1/2" Vinyl Covered Tackable
- Surface, 100% recycled content
Ceiling
- Suspended acoustical ceiling with Noise Reduction Coefficient of 65% min. and light reflectance of 85% min. (25% recycled content min)
Casework
- Teaching wall & large built in locking AV cabinet
- Constructed of Agri-Fiber composite panels with Ureaformaldehyde free adhesives to improve indoor air quality
Green Building Systems
Mechanical
- Energy saving Bard 4 ton wall mounted dual stage heat pump (14.5 IPLV rating)
- Ventilation controller to monitor & reduce CO2 level
- 1” duct noise attenuation material to reduce HVAC noise level
Electrical
- Suspended linear fluorescent lighting, Super T-8 28watt lamps, high efficiency electronic ballasts (only 78 watts per sq ft)
- Occupancy motion sensor turns off general lighting when room is vacant
- Daylight Control Sensor eliminates artificial lighting when not needed
Technology
- Centrally located Teacher Control Center (TCC) includes main AV control
- 'Quiet Time Switch' linked to TCC and lighting controls
- AV & technology infrastructure (conduit installed in key locations)
- Integrated KMC building automation system to improve energy efficiency
US Green Building Council LEED™ Version 2.2
Credit Summary for Modtech Holdings, Inc. - Green Classroom Building
The following summary demonstrates the LEED™-NC V2.2 credit potential of this building prior to being installed on site. This building or series of them can be a great starting point to achieving a USGBC LEED™ Certified project.
SS - Sustainable Sites (Cool Roof)
EA – Energy & Atmosphere
MR – Materials & Resources
IEQ – Indoor Environmental Quality
ID – Innovation and Design Process
Total Credits: 28 as designed without being sited
Total Required for Certification: 26 minimum to receive LEED™ Certification
CHPS Relocatable Classroom Specifications
Main Focus
- Quieter interior with better air quality and greater comfort
- Reduced energy consumption (minimum reduction of at least 20%)
Size
- 24x40 for a usable area of 960 sq ft.
Green Features
- Cool Roof system (light reflectance of 70%) to reduce heat transferred into interior spaces
- Separate lighting system for teaching area allowing for greater visibility
- Six tubular skylights that promote day-lighting as well as reduce/eliminate the need for artificial lighting (with dampers and light diffusers for solar control)
- Overhangs at either end of building to shade windows and reduce heat transfer
- Operable, 8x4 anodized aluminum frame windows with low e, dual glazing for greater day lighting and reduced thermal heat gain/loss
- HVAC interlock on windows to prevent HVAC operation when opened
- High efficiency, quiet operation wall mounted heat pump with economizer to utilize 100% outside air when conditions are suitable
- HVAC balancing box to ensure all four ceiling diffusers distribute air evenly
- Silencer on HVAC return duct to reduce noise
- Programmable or communicating thermostats
- Pendant mounted direct / indirect dual mode luminaires (32 watt T8 lamps using 28 watts or less per lamp)
- A/V teacher control switch to manage lighting adjacent to teaching station
- Orient classroom so windows are facing North and South to limit the amount of direct sun on windows
- Occupancy sensors will terminate artificial lighting when room is unoccupied
- Light colored materials with a high light reflectance and noise absorbent interior wall finishes
- Low emitting materials throughout interior spaces
Options, features, specifications, and colors may change without prior notification. Please consult your sales representative for latest information.